xiii
Preface
Environmental Standards
Climatic and Atmospheric Specifications
The servers comply with standards:
• IEC 60068.2.1
IEC 60068.2.2
IEC 60068.2.78
IEC 60529
IEC 60950
ISO 7779
Electrical Specifications
The servers comply with standards:
• IEC 60038
IEC 60059
IEC 60196
IEC 60364
IEC 61689
Mains Source Power
• 207-244 VAC, 49 - 61 Hz (single phase Ph / N + PE or Ph / Ph + PE),
20/32/64A per PDU (see model specifications)
Voltage Sag
• 20 ms (IEC 1000-4-11)
Electromagnetic Compatibility
The servers comply with standards:
Europe:
EMC Directive, 89/336/EEC
• EN55022, Class A Limit, Radiated & Conducted Emissions
• EN55024, ITE Specific Immunity Standard
• EN61000-4-2, ESD Immunity (Level 2 Contact Discharge, Level 3 Air Dis-
charge)
• EN61000-4-3, Radiated Immunity (Level 2)
• EN61000-4-4, Electrical Fast Transient (Level 2)
• EN61000-4-5, AC Surge
• EN61000-4-6, Conducted RF
• EN61000-4-8, Power Frequency Magnetic Fields
• EN61000-4-11, Voltage Dips and Interrupts
• EN61000-3-2, Limit for Harmonic Current Emissions
• EN61000-3-3, Voltage Flicker
North America • FCC Part 15 Class A
• ICES-003 Issue 3 Class A
Bull NovaScale Blade servers also comply with standards:
• Japan: IEC 1000-3-2
• Australia / New Zealand: IEC 60950
• Taiwan: BSMI Approval
• Korea: RRL Approval
• Russia: GOST Approved
• International: CISPR, Class A Limit
Comments to this Manuals