Delivery 1-3
1.1.3 Installation Environment
Warning:
Ensure that the operational environmental conditions fiven hereafter are satisfied.
Operational Environment
Altitude:
Operational: -30 to 1524 m (-100 to 5000 ft)
Temperature (*1)
Operational: 5 to 35° C (max rate change: 10° C/h)
Non-operational: -10 to 43° C (max rate change: 10° C/h)
Relative Humidity:
Operational: 20 to 80%
Non-Operational: less than 95%, non-condensing at 25 to 30° C
*1:
If installed in a closed or multi-unit rack assembly, the operating ambient
temperature of the rack environment may be greater than room ambient.
Therefore, consideration should be given to installing the equipment in an
environment compatible with the maximum ambient temperature specified in
this section
1.2 Unpacking the Server Cabinet
Instructions on how to unpack the cabinets for Bull NovaScale Servers and peripheral
devices are set out in document Bull 1100 & 1300 Cabinet Installation & Service Guide,
86 A1 91EM.
1.3 Unpacking and Installing a Server Drawer
Instructions on how to unpack the server drawer are set out in the documentation shipped
with the server.
For instructions on how to mount the server drawer in the cabinet, please refer to
Appendix B. Mounting the Server Drawer in the Cabinet.