Bull NovaScale 3005 Series User's Guide Page 49

  • Download
  • Add to my manuals
  • Print
  • Page
    / 158
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 48
Getting Started 2-25
2.4.4.3 Power Supply Indicators
# Components Description
A Input Good LED Indicates input power is good, when LED (green) is on.
B DC Output Good LED Indicates output power is good, when LED (green) is on.
C Fault LED Indicates the Power Supply is faulty
Figure 2-23. NovaScale 3045 COMPACT Power Supply Indicators
2.4.5 Cooling Subsystem
2.4.5.1 Cooling Overview
The cabinet inlets have 6 non-redundant fans for cooling. These fans are not hot-swappable.
The AC unit has non-redundant fans in it for cooling the AC unit.
2.4.5.2 Cooling Structure
The 65x66.7mm fans are used. They provide enough airflow to cool server components,
CPU, memory and chipset without redundancy. Each fan is placed around the center of the
cabinet and memory respectively. HDD and DVD are cooled by suction. Components on
main board, CPU and chipset are cooled by airflow through the air duct.
CAUTION:
The server drawer top cover must be installed and closed for proper system cooling.
C
!
A
B
Page view 48
1 2 ... 44 45 46 47 48 49 50 51 52 53 54 ... 157 158

Comments to this Manuals

No comments