Summary of Contents

Page 1 - NovaScale

NovaScaleServersSite Preparation Guide NOVASCALEREFERENCE86 A1 87EF 08

Page 2

viiiSite Preparation GuideList of TablesTable 1. NovaScale Blade 20xx cabinet specifications A-3. . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 3 - NovaScale Servers

ixPrefaceIntended ReadersThis Site Preparation Guide explains how to prepare a Data Processing Center for Bullservers, in compliance with the standard

Page 4

xSite Preparation GuideGeneral RecommendationsIt is mandatory to comply with the procedures, design requirements and recommendations setout in this gu

Page 5 - Table of Contents

xiPrefaceRegulatory Specifications and DisclaimersDeclaration of the Manufacturer or ImporterWe hereby certify that this product is in compliance with

Page 6

xiiSite Preparation GuideFederal Communications Commission (FCC) StatementNote:This equipment has been tested and found to comply with the limits for

Page 7

xiiiPrefaceEnvironmental StandardsClimatic and Atmospheric SpecificationsThe servers comply with standards:• IEC 60068.2.1IEC 60068.2.2IEC 60068.2.78I

Page 8

xivSite Preparation GuideProtection against Electrostatic DischargesCMOS (Complementary Metal Oxide Semiconductor) technology is highly sensitive toel

Page 9 - List of Figures

xvPrefacePollution LimitsThe servers comply with standard:• NFX44-101, Class 4 000 000Audio-Noise LimitsThe servers comply with standards:• ISO 7779•

Page 10 - List of Tables

xviSite Preparation Guide

Page 11 - Definition of Safety Notices

1-1General RecommendationsChapter 1. General RequirementsThis chapter explains delivery and unpacking requirements for the servers. It includes the fo

Page 13 - Safety Compliance Statement

1-2Site Preparation GuideDelivery ConditionsThe server is delivered 24 hours in advance of the scheduled installation date. On arrival, the server mus

Page 14 - Laser Compliance Notice

1-3General RecommendationsUnpacking RequirementsThe cabinet is delivered packed on a pallet with rails for easy unloading. The Data Processing Site ma

Page 15 - Environmental Standards

1-4Site Preparation Guide

Page 16 - Shocks and Vibrations

2-1Fitting out the PremisesChapter 2. Fitting out the PremisesThis chapter explains how to plan and fit out your premises to receive your server. It i

Page 17 - Safety Specifications

2-2Site Preparation GuideFor optimum site safety and security, the following figure shows an example of recommendedData Processing Center layout.MEDIA

Page 18 - Site Preparation Guide

2-3Fitting out the PremisesPlanning InstallationInstallation must be planned so that any changes and / or extensions may be implementedwith minimum se

Page 19 - Server Cabinets

2-4Site Preparation GuideNetwork CablesThe following table indicates the number of Ethernet and Modem cables to be routed to thecable cut-out at the b

Page 20 - Carry-In Route

2-5Fitting out the PremisesService ClearanceIt is mandatory to comply with the service clearance requirements indicated in the followingfigures:100 cm

Page 21 - Unpacking Requirements

2-6Site Preparation Guide1 square = 60 x 60 cmFigure 7. Layout grid

Page 22

2-7Fitting out the PremisesElectrical / Electromagnetic InterferenceGenerators of electromagnetic interference may adversely affect server operation.

Page 23 - Data Processing Center Layout

NOVASCALENovaScale ServersSite Preparation GuideDecember 2006BULL CEDOC357 AVENUE PATTONB.P.2084549008 ANGERS CEDEX 01FRANCEREFERENCE86 A1 87EF 08Hard

Page 24 - COMPUTER

2-8Site Preparation GuideExtinguishing AgentsIn compliance with APSAD R13.Commonly used extinguishing agents are:• inert gases such as ARGONITE (Argon

Page 25 - Planning Installation

2-9Fitting out the PremisesComputer Room FloorPrimary FloorThe primary floor must be sloped and equipped with a drain.Primary floor resistance must be

Page 26 - Network Cables

2-10Site Preparation GuideActuators aloneActuators and T–beam section sparsFigure 9. Raised floor structureCAUTION:If the air-conditioning unit(s) is

Page 27 - Service Clearance

2-11Fitting out the PremisesSound-ProofingThe sound level in the Computer Room may be relatively high due to room structure,air-conditioning and hardw

Page 28 - Figure 7. Layout grid

2-12Site Preparation GuideMedia Storage RoomMedia may be stored in the Computer Room or in an adjacent room, in which caseComputer Room environmental

Page 29 - Fire Protection

3-1Air ConditioningChapter 3. Air-ConditioningThis chapter explains air-conditioning requirements for the servers. It includes the following topics:•

Page 30 - Water Damage

3-2Site Preparation GuideAir-Conditioning System SpecificationsWarning:If the air-conditioning system is shut down, "operational" conditions

Page 31 - Computer Room Floor

3-3Air ConditioningCirculationThe servers are cooled by taking air from inside the room. The following requirements are tobe complied with for correct

Page 32 - Computer Room Ceiling

3-4Site Preparation GuidePollutantsThere are three types of pollutants:• liquids,• solid particles,• gases.Damage varies according to pollutant type a

Page 33 - Cleaning

3-5Air ConditioningChecks and AlarmsThe air-conditioning system is controlled automatically. Variations outside the specifiedtemperature and hygrometr

Page 34 - Ancillary Equipment Room

The following copyright notice protects this book under Copyright laws which prohibit such actions as, but notlimited to, copying, distributing, modif

Page 35 - Chapter 3. Air-Conditioning

3-6Site Preparation Guide

Page 36

4-1Power SupplyChapter 4. Power SupplyThis chapter explains power supply requirements for Bull NovaScale Servers. It includes thefollowing topics:• Po

Page 37 - Air Conditioning

4-2Site Preparation GuideDANGER• To ensure the protection of personnel and equipment, bipolar magneto-thermic circuitbreakers must be installed on the

Page 38

4-3Power SupplyMounting Power Supply Cable SocketsCAUTION:To be performed by a certified electrician only.Tools Required• Multimeter• Phillips screwdr

Page 39 - Checks and Alarms

4-4Site Preparation GuideFor PDU/UPS equipped with IEC 60309 plugs.1. Check that the power supply cable is not live with the multimeter.2. Carefully g

Page 40

4-5Power SupplyGrounding CircuitThe electronic components inside the servers are sensitive to high-frequency electromagneticinterference. To ensure co

Page 41 - Chapter 4. Power Supply

4-6Site Preparation GuideFigure 15. Raised floor equipotentiality methodNeutral Power SystemA TN-S neutral point connection system is mandatory for th

Page 42 - Cabling Requirements

4-7Power SupplyNNP.EMain earthplate terminalRaised floor actuator meshing braidData processingequipotential barP.EY/GMeasurement barElectricityPower S

Page 43 - Power Supply

4-8Site Preparation GuideNon-Computing Power SupplyPrerequisites• Installation of current outlets around the edge of the computing room.• The non-comp

Page 44

A-1Specifications and FeaturesAppendix A. Specifications• NovaScale 20xx cabinet specifications, on page A-2• NovaScale 20xx chassis specifications,

Page 45 - Grounding Circuit

iiiPrefacePrefaceTable of ContentsPreface iii. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 46 - Neutral Power System

A-2Site Preparation GuideNovaScale Blade 2xxx Cabinet SpecificationsNovaScale Blade chassis are delivered rack-mounted in a 19U or 40U cabinet.Cabinet

Page 47

A-3Specifications and FeaturesElectrical Specifications (power supplies are auto-sensing and auto-ranging)Power consumptionThermal dissipation5000 VA

Page 48 - Non-Computing Power Supply

A-4Site Preparation GuideNovaScale Blade 20xx Chassis SpecificationsDimensions / WeightHeight 30.42 cm (23.25 in, 7U)Width 44.4 cm (17.5 in)Depth

Page 49 - Appendix A. Specifications

A-5Specifications and FeaturesNovaScale Blade 2020 Server SpecificationsDimensions / WeightHeight 24.5 cm (9.7 in)Width 2.9 cm (1.14 in)Depth 44.

Page 50

A-6Site Preparation GuideNovaScale Blade 2320 Server SpecificationsDimensions / WeightHeight 24.5 cm (9.7 in)Width 2.9 cm (1.14 in)Depth 44.6 cm

Page 51 - Specifications and Features

A-7Specifications and FeaturesNovaScale 3005 Series Server Cabinet SpecificationsThe Novascale 3005 Series are delivered rack-mounted in a 19U or 40U

Page 52 -  F) (-40 to 140 F)

A-8Site Preparation GuideElectrical specifications(power supplies are auto-sensing and auto-ranging)Current drawPower consumptionThermal dissipation24

Page 53

A-9Specifications and FeaturesNovascale 3025 Server CPU Drawer SpecificationsDimensions/WeightHeight:Width:Depth:Weight (base model)Weight (max)17.6 c

Page 54 - Electrical

A-10Site Preparation GuideNovaScale 3045 Server CPU Drawer SpecificationsDimensions/WeightHeight:Width:Depth:Weight (base model)Weight (max)17.6 cm (6

Page 55

A-11Specifications and FeaturesNovaScale 3045 COMPACT Server CPU Drawer SpecificationsDimensions/WeightHeight:Width:Depth:Weight (base model)Weight (m

Page 56

ivSite Preparation GuideChapter 2. Fitting out the Premises 2-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dat

Page 57

A-12Site Preparation GuideNovaScale 4020/4040 Server Cabinet SpecificationsNovaScale 4020 / 4040 servers are delivered rack-mounted in a 40U or 19U ca

Page 58

A-13Specifications and FeaturesElectrical Specifications (power supplies are auto-sensing and auto-ranging)Power consumptionThermal dissipation8800 VA

Page 59

A-14Site Preparation GuideNovaScale 4020 Server CPU Drawer SpecificationsDimensions / WeightHeight 8.77 cm (3.5 in, 2U)Width 44.9 cm (17.7 in)Depth 74

Page 60

A-15Specifications and FeaturesNovaScale 4040 Server CPU Drawer SpecificationsDimensions / WeightHeight 17.53 cm (6.9 in, 4U)Width 44.45 cm (17.5 in)D

Page 61

A-16Site Preparation GuideNovaScale 5080/5160/6080/6160 SpecificationsNovaScale 5080/5160 Servers are delivered rack-mounted in 40U cabinets.Cabinet D

Page 62 -  F) (-40 to 158 F)

A-17Specifications and FeaturesPower CablesPDU-0-7-M-32AAC (32A)Cable typeConnector type1 per PDU3 x AWG10 ( 3 x 6 mm2 / #10US)IEC60309-32ACSS ModuleA

Page 63

A-18Site Preparation GuideNovaScale 5320/6320 Server SpecificationsCabinet Dimensions / WeightUnpacked PackedHeight: 177.5 cm (70 in)Width: 65.0 cm

Page 64

A-19Specifications and FeaturesPower CablesPDU-0-7-M-32AAC (32A)Cable typeConnector type1 per PDU3 x AWG10 ( 3 x 6 mm2 / #10US)IEC60309-32ACSS ModuleA

Page 65

A-20Site Preparation GuideNovaScale 5085 Server SpecificationsNovaScale 5085 Servers are delivered rack-mounted in 40U or 19U cabinets.Cabinet Dimensi

Page 66

A-21Specifications and FeaturesPower CablesPDU-2-4-M-32AAC (32A)Cable typeConnector type1 per PDU3 x AWG10 ( 3 x 6 mm2 / #10US)IEC60309-32AIt is manda

Page 67

vPrefaceGrounding the Raised Floor 4-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Neutral Power System 4

Page 68

A-22Site Preparation GuideNovaScale 5165 Server SpecificationsNovaScale 5165 Servers are delivered rack-mounted in 40U or 19U cabinets.Cabinet Dimensi

Page 69

A-23Specifications and FeaturesAcoustic Power at Room Temperature +20° C (+68° F)System Running System IdleLw(A) 6.3 Bels Lw(A) 6.1 BelsPower CablesPD

Page 70

A-24Site Preparation GuideNovaScale 5245 Server SpecificationsNovaScale 5245 Servers are delivered rack-mounted in 40U cabinets.Cabinet Dimensions / W

Page 71 - ° C (+68° F)

A-25Specifications and FeaturesPower CablesPDU-2-4-M-32AAC (32A)Cable typeConnector type1 per PDU3 x AWG10 (3 x 6 mm2 / #10US)IEC60309-32AIt is mandat

Page 72

A-26Site Preparation GuideNovaScale 5325 Server SpecificationsNovaScale 5325 Servers are delivered rack-mounted in 40U cabinets.Cabinet Dimensions / W

Page 73

A-27Specifications and FeaturesPower CablesPDU-2-4-M-32AAC (32A)Cable typeConnector type1 per PDU3 x AWG10 (3 x 6 mm2 / #10US)IEC60309-32AIt is mandat

Page 74

A-28Site Preparation GuideSmart UPS ReferencesUPS Type 3KVA 5KVA 7.5KVA 10KVADimensions/WeightHeigthWidthDepthWeight8.9cm (3.5in)48.3cm (19in)66cm (26

Page 75

B-1Appendix B - Conversion TablesAppendix B. Conversion TablesImperial to Metric1 inch (") 2.54 cm (centimeters)1 foot (') (12 inches) 30.48

Page 76 - Smart UPS References

B-2Site Preparation GuideCelsius to Fahrenheit ConversionMultiply the temperature in Celsius by 9, divide by 5 and add 32:(C x 9/5) + 32 = FFahren

Page 77 - Appendix B. Conversion Tables

IndexX-1IndexAAircirculation, 3-3distribution, 3-2filtering, 3-2pollution, 3-2renewal, 3-2Air conditioning, 3-1features, 3-1functions, 3-1specificatio

Page 78 - (F - 32) x 5/9 = C

viSite Preparation Guide

Page 79

X-2Site Preparation GuideSite, layout grid, 2-6Sound-proofing, 2-11Specificationsair-conditioning, 3-2Blade 2020, A-5Blade 2021, A-5Blade 2040, A-5Bla

Page 80

Technical publication remarks formTitle : NOVASCALE NovaScale Servers Site Preparation Guide Reference:86 A1 87EF 08Date:December 2006ERRORS IN PUBLI

Page 81 - ADDRESS :

Technical publications ordering formTo order additional publications, please fill in a copy of this form and send it via mail to:BULL CEDOC357 AVENUE

Page 83

BULL CEDOC357 AVENUE PATTONB.P.2084549008 ANGERS CEDEX 01FRANCE86 A1 87EF 08REFERENCE

Page 84 - REFERENCE

Utiliser les marques de découpe pour obtenir les étiquettes.Use the cut marks to get the labels.86 A1 87EF 08NovaScale ServersSite PreparationGuideNOV

Page 86

viiPrefaceList of FiguresFigure 1. Bull server cabinets 1-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Comments to this Manuals

No comments